Distributor improvements on all V4 embossers-X
User and service interface
- LED feedback from the front panel, the main (mother) board and LED board provide information regarding embosser status, position of sensors, communication etc.
- The speech feedback language may switch between local languages and English found on the front panel, making service on embossers with local languages easier.
- Multilingual user manuals are available on the embosser and may also be embossed by the user.
- Marketing and test documents are available for all embossers and may be embossed by the user.
- The command center for settings and the monitoring of all user and service commands come directly from your PC.
- Embedded web server to monitor embosser status, monitor and edit setup values, and upgrade embosser firmware/speech.
- Automatic on-line firmware check and upgrade.
- The internal operation system etc. may be downloaded from your computer, available also in the instance of complete removal of the program.
- Save the embosser settings, serial number etc to the mini flash card, move all value to a new board simply by relocating the Flash card.
- Local speech feedback is easier to develop, including few limitations in the number of words and the size of recorded speech files.
- Embossing log files are available for monitoring embosser status and the status of the last embossed documents.
Mechanical construction
- The V4 embossing head has the following significant improvements: individually exchangeable hammers (< 60 seconds), plastic foil in which holds the paper against the anvils is integrated as part of the Al-profile, and hammers with new bearing material in which increase the life cycle.
- All screws and nuts are made following the best industry standards.
Electronic hardware
- The technical core of the V4 is a LINUX based computer combined with additional low level CPU's that control the embossing process. Basic-D and Everest are based on the same mother board and internal firmware.
- The V4 main board also includes interface connectors. Therefore, it is no longer necessary for a separate interface board, cables etc.
- Energy saving settings may be adjusted from the front panel.
- Main board temperature values are available in the log files.